Service Manual

The grinder pump is designed to grind and pump domestic sewage. The pump is a semi-positive displacement, progressing cavity pump. The grinder pump consists of a pump assembly with an integral sewage grinder and shredder device. The pump traps a column of air in the sensing column for the On–Off Pressure Switch. When water in the tank …

Duplex Demand Control Panel

Alternating Relay for Pump Alternation with Selector Switch; Pump Hand-Off-Auto Switch with Pump Running Light; Full Alarm Circuit (Visual and Audible Alarms) Alarm Test and Silence Switch; Color Coded Internal Wiring; Connection Diagram and Schematic; 4 Float System (Off, On, Lag and High Water) Built and Labeled to UL 508A Standard; Spec Sheet

4 grinder pump panel with mercury switch

4 Grinder Pump Panel With Mercury Switch MCC . 1 2HP Grinder Pump / 230 Volts 1 Phase 1 Alarm Panel with Float Switch for WD820 Systems or Simplex Control Panel with Auto Reversing for E840 Systems 1 Junction Box 3 Float Switches (E840 Systems only) 48" contain mercury 60" 72" 84" 2" ELECTRICAL PVC PIPE 2" GROMMET SEAL …

SJE PumpMaster®

The SJE PumpMaster® pump switch is designed to directly control pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC in water and sewage applications. The SJE PumpMaster® pump switch is not sensitive to rotation or turbulence, allowing it to be used in both calm and turbulent applications. Check out the new SJE PumpMaster® Quick Fit pump switch ...

Switches Archives

15′ 13 Amp Single Piggyback Variable Level Float Switch. 10-0034. The 15' single piggyback variable level float switch allows you to adjust the on/off points on a nonautomatic pump rated for 115 V and 13 amps or less. The switch can be used in a variety of applications including sump,...

Package Pumping Station | Mercury | T-T Pumps

The Mercury package pumping station, from T-T's BBA-approved Planet Range, is an efficient and economical sewage/drainage pumping solution complete with pre-assembled internal pipework for rapid installation. With a polyethylene chamber, rigorous in-house testing and a high-efficiency range of compatible pumps available, the Mercury pump …

Duplex Demand Control Panel

Pump Hand-Off-Auto Switch with Pump Running Light; Alternating Relay for Pump Alternation with Selector Circuit; Full Alarm Circuit (Visual and Audible Alarms) Alarm Test and Silence Switch; Color Coded Internal Wiring; Connection Diagram and Schematic; 4 Float System (Off, On, Lag and High Water) Built and Labeled to UL 508A Standard; FLA ...

Specifications 3 – 7-1/2 HP DUPLEX GRINDER PUMP …

GRINDER PUMP BASIN PACKAGE WITH DIRECT MOUNTED CONTROL PANEL Model Numbers: B20R-4872, B20R-48192 ... (4) mercury tube float switches. Switches shall consist of a mercury tube switch sealed in a corrosion-resistant polypropylene housing with a minimum of 18 gauge jacketed cable. The cable shall be of sufficient length to …

Simplex Grinder Control Panel

208/240 Single-Phase Simplex Grinder Control Panel; 4x Rated Durable, Weather-Resistant Enclosure with Mounting Feet and Stainless Steel Latch; Circuit Breaker for …

Grinder pump | Grundfos

A sewage grinder pump is a centrifugal pump equipped with a grinder system at the pump inlet, which cuts larger particles and fibres into a homogeneous wastewater mass. …

922 Duplex Prepackaged System with E840

Product Details. Our prepackaged basin assembly is everything you need to install your whole system as one item. This includes two model E840 grinder pumps, 36″ x 60″ basin assembly, duplex control panel, and float switches. Solids are cut into a slurry using the industry proven "scissor like" Tri-Slice ® cutter technology.

4 grinder pump panel with mercury switch

10 AMP Mercury Switches - Float Switches - Grinder Pumps - 4 grinder pump panel with mercury switch - parkbankduo.de. Section 8 Grinder Pumps. The location of the grinder pump package and control panel shall be, Grinder Pumps 8-4 April pump turn-off A third switch shall be provided for high water alarm and, On sump level rise, lower mercury …

Champion Grinder Pump

1 HP Grinder Pump & HF2OU10F1 10' Float Switch. Easy to install, rugged, heavy duty, cast iron, 1 HP grinder pump that have a 1-1/4" vertical discharge and grinds sewage into a slurry and will help reduce clogging found in various wastewater applications. The grinder pump produces capacities up to 42 gpm with heads up to 55 feet.

Barnes Retrofit MDI Grinder Pump

The recessed vortex impeller design of the Barnes retrofit grinder pump provides trouble free, non-overloading operation over the entire performance curve. The Barnes retrofit pump produces capacities to 47 …

Champion Grinder Pump

The vortex impeller design of the grinder pump provides non-overloading performance and prevents clogging. This grinder pump produces capacities up to 42 gpm with heads up to 133 feet. Features; Performances. Heads Up to 133' TDH; Flows Up to 42 GPM; Strong 2 HP Motor. 60 Hz Single-Phase; 15 AMPS @ 230 VAC; Vertical Discharge 1-1/4" Max …

Grinder Pumps Selection Guide: Types, Features, …

Grinder Pumps Information. Grinder pumps are centrifugal pumps equipped with shredding systems to aid in the transport of solids filled media. The cutting devices facilitate solids maceration and shredding to …

15' Double Piggyback Variable Level Float Switch

Homeowners. The 15' double piggyback variable level float switch allows you to adjust the on/off points on a nonautomatic pump rated for 115 V and 13 amps or less. The switch …

Model 820 Grinder Pump with Switch

The 230 Volt, 2 HP, Model 820 utilizes a vortex impeller. The WD820, is a fully automatic float-operated grinder pump with a wide-angle float switch hardwired directly into the pump allowing it to turn on when called upon. The Model 820 is constructed with a cast iron body, enabling it to withstand the most demanding sewage ejector applications.

Duplex Grinder Control Panel

Duplex Grinder Control Panel - 208/240 Single-Phase (Separate Pump & Control Circuit) SKU: 50A750-C20-NF. Price: ... Alternating Relay with Selector Switch; Pump Hand-Off-Auto Switch with Pump Running Light; Full Alarm Circuit (Visual and Audible Alarms) ... Mercury or Mechanical Float Switches for the Pumps and High Water Alarm …

Septic Tank Float Switches

Sewage Grinder Pumps. Effluent Pumps. Sump Pumps. Utility Pumps. Sprinkler Heads. Complete Pump Systems. ... Control duty float switches are designed to be connected directly to a control panel to tell the control panel when to turn the pump on an off, or to signal the high level or low level alarm based upon the liquid level inside your tank ...

Wastewater Pumps, Grinder Pumps, Custom Basin Packages, Shredder Pumps

Level Controls & Panels. Mercury Hg Floats. Mini Pilot Duty | Control Floats; Pilot Duty | Control Floats; ... 20 foot cord - 64 GPM - 48 foot Head w/ Vertical Switch. SKU: CPE5-12 V Quote Only. Champion Grinder Pump - 2HP - 208V/230V - (42 gpm & 133 foot head) - Internal Cap. Start - High Head - Float Included. SKU: CPGH2023DS Quote Only ...

Specifications 3 – 7-1/2 HP DUPLEX GRINDER PUMP …

GRINDER PUMP BASIN PACKAGE WITH REMOTE MOUNTED CONTROL PANEL Model Numbers: B20RO-4872, B20RO-48192 ... (4) mercury tube float switches. Switches shall consist of a mercury tube switch sealed in a corrosion-resistant polypropylene housing with a minimum of 18 gauge jacketed cable. The cable shall be of sufficient length to …

4 grinder pump panel with mercury switch

Section 8 Grinder Pumps. The location of the grinder pump package and control panel shall be ... Grinder Pumps 8-4 April 2018 pump turn-off. A third switch shall be provided for high water alarm and ... On sump level rise, lower mercury switch shall first be energized, then upper level switch shall next energize and start pump. With pump ...

Simplex Grinder Pump Control Panels | Franklin Water

Alarm ON/OFF switch controls the power to audible and visual alarm signal device; cULus listed; Order Information. Single Phase Control Panels. Item Model Description; 515357: A-SF230CBG-121: Simplex Grinder Control Panel, 230V, 1PH, FLA: 14.0 : 515364: 1121W124X: Simplex Grinder Control Panel, 208-230V, 1PH, FLA: 15-20 ... Brochures …

Float Switches

Sump Alarm. Float Switches; Pump Type: Float Switch; For Use With: Sump/Grinder Pumps; Float Style: Weighted Control Float Switch; Voltage (AC): 3.3V DC; 120V AC ...

Grinder Pump Control Panels | Franklin Water

Our grinder pump control panels come equipped and ready to help with any IGP manual grinder series. Franklin Electric's grinder pump control panels are equipped with …

Grinder Pump

The grinder pump produces capacities to 68 gpm with heads to 95 feet. The grinder pump retrofits into many existing competitor pump installations. The grinder pump operates with the same control panel …

Duplex Grinder Pump Control Panels | Franklin Water

Controls the pump and warns of high liquid levels. Color-coded terminal strip for ease of installation. Corrosion-resistant NEMA 4X fiberglass, waterproof enclosure with padlock …

AE24H=4

Description. –. AE Series Duplex Control Panel 115/230V, NEMA 4X, 1 Phase, 15 - 20 amps (4 Floats) Features: Magnetic Motor Contactors. HOA switches (internal) Green …

4 grinder pump panel with mercury switch

1 Phase Duplex Control Panel Grinder & Vortex Pumps. 4 Float: With both "HOA" switches in "Auto" and the pump selector switch in "ALT": On water rise, the "off/stop" float will close and when the level closes the "lead" float, pump • MRG20 2 HP grinder pump 230V, 1Ø • 30" x 36" FRP basin • Steel cover • Check valve • Two SDR35 inlet hubs and Sch 40 …